NGHIÊN CỨU TÌNH HUỐNG

In a high-precision semiconductor plant, a critical incident arose when a highly acidic process pipe developed a leak. With production continuity at stake, a full shutdown was not feasible, presenting both operational and safety challenges. To address the situation, our customer conducted a comprehensive pre-survey and leakage assessment of the affected area. Based on these findings, a composite box-up repair solution was implemented using Alchem’s C-SmartSeal products delivering a durable repair that restored integrity and safety while ensuring uninterrupted
operations.
Site conditions:
Pipe Material: PVC
Pipe Size: DN80
Medium Type: Diluted copper waste solution Copper Concentration: < 5 ppm
pH range: 1–2 (highly acidic)
Temperature: Room temperature
Pressure: Hydrostatic (gravity drain system)
Materials Used in Repair:
PTFE Tape - for chemical-resistant sealing
Smartstic Epoxy Stick- for leak repair
Corsmart Resin and Activator- for durable sealing and chemical resistance
Liquid Putty + Uncoated Fiberglass Tape-for surface reinforcement and leak prevention