CASE STUDIES
TECHNICAL DETAILS
Pipe Material: PVC (Polyvinyl Chloride)
Pipe Diameter: 150 mm
Pipe Medium: Industrial Waste Water
Leak Condition: 150 mm crack on T-Joint
System Pressure: 4 Bar
LEAK CONDITIONS
Leak was found on a PVC T-Joint with a crack line of 150 mm. The system was holding a pressure of 4 Bar. Repairing the T-joint with WRAP-PRO Standard Repair Clamp was not feasible due to the odd shape of the pipe fittings. Alstern’s specialist team was activated to provide immediate repair with C-SMARTSEAL Composite Repair Products.
LEAK REPAIR SOLUTION
Composite Live Leak Repair was carried out without interruption to overall system operation. SMARTSTIC Epoxy Stick Underwater was kneaded to 80% cure and applied to the leak area, supported by WRAP-PRO Stainless-Steel Pipe Clip. A gap of 60 minutes was observed to ensure leak at T-Joint had stopped. Then, self-fusing QUIKCONTROL Sealing Tape was wrapped to provide water-proofing, follow by this QUIKCONTROL Fiberglass Repair Tape was wrapped to reinforce PVC pipe strength.